Repair and operation of the car of Audi 100/A6 - 3.2.2.17. Oil pump and maslozaborny branch pipe//Audi of 100/A6 1990-1997 / t3r.ru

Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
- 3.2. Diesel engines
   + 3.2.1.2. Technical characteristics
   - 3.2.2. 5-cylinder engines
      3.2.2.2. Technical characteristics
      3.2.2.3. Sinkhronizatsionnye of a gazoraspredeleniye label
      3.2.2.4. Compression check
      3.2.2.5. Gas-distributing belt
      3.2.2.6. Driving belt of the fuel pump
      3.2.2.7. Natyazhitel of a gas-distributing belt and asterisk
      3.2.2.8. Additional driving belt
      3.2.2.9. Camshaft cover
      3.2.2.10. Camshaft epiploons
      3.2.2.11. Epiploons of a cranked shaft
      3.2.2.12. Head of cylinders
      3.2.2.13. Hydraulic pushers
      3.2.2.14. Flywheel
      3.2.2.15. Engine fastenings
      3.2.2.16. Oil pallet
      3.2.2.17. Oil pump and maslozaborny branch pipe
+ 3.3. Removal and partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
+ 6. Fuel system
+ 7. Exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
+ 11. Suspension brackets, steering
+ 12. Body
+ 13. Electric equipment
+ 14. Good advice


ff85f19c
Èíòåðåñíîå

3.2.2.17. Oil pump and maslozaborny branch pipe

Removal

PERFORMANCE ORDER
1. Remove a gas-distributing belt and an asterisk of a cranked shaft.
2. Remove the oil pallet.
3. Remove the ventilating channel in a back part of the block.
4. Remove a lock ring of the filter of a maslozaborny branch pipe.
5. Remove the filter (AAT).
6. Unscrew branch pipe bolts.
7. Unscrew bolts of an arm of a branch pipe.
8. Remove a branch pipe.
9. Get a sealing ring.
10. Unscrew bolts and remove the oil pump.
11. Remove pump laying.

Check

PERFORMANCE ORDER
1. Uncover the pump.
2. Unscrew a cap of the reduktsionny valve.
3. Get a washer, a spring.
4. Get the piston (AAT).
5. Examine all details of the pump and the valve on existence of wear and damages.
6. If necessary replace an epiploon of a cranked shaft.
7. Collect the pump and the reduktsionny valve. Tighten a cap of the reduktsionny valve (AAT).

Installation

Installation is made in sequence, return to removal.