Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
+ 3.2. Diesel engines
+ 3.3. Removal and partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
- 6. Fuel system
   + 6.1.2. Technical characteristics
   + 6.2. Multipoint system of injection of fuel
   - 6.3. System of injection of MPI/MPFI (6-cylinder engines)
      6.3.2. Technical characteristics
      6.3.3. Distinctions of systems of injection
      6.3.4. Sensors
      6.3.5. Idling regulation
      6.3.6. Removal and installation of klapanny nozzles
      6.3.7. Check of klapanny nozzles
      6.3.8. Oxygen sensor
   + 6.4. Power supply system of diesel engines
   6.5. Device of service of heating
   6.6. Diagnostics of malfunctions of system of heating
   6.7. Conditioner: not only "pluses", but also "minuses"
   6.8. Rules of service of the conditioner
+ 7. Exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
+ 11. Suspension brackets, steering
+ 12. Body
+ 13. Electric equipment
+ 14. Good advice


ff85f19c

6.3.8. Oxygen sensor

GENERAL INFORMATION

Connections of vacuum pipelines (the 6-cylinder engine in capacity of 174 hp)

1. Amplifier of brake system
2. Noise quencher
3. The mechanical valve of system of a retsirkulyatsiya of the fulfilled gases
4. Membrane mechanism of perepuskny valves of an inlet collector
5. Butterfly valve knot
6. A switched inlet collector
7. Regulator of pressure of fuel

8. Vacuum pump
9. The electromagnetic valve of system of a retsirkulyatsiya of the fulfilled gases
10. Valve of management of switching of valves of an inlet collector
11. Capacity of an inlet collector
12. Air filter
13. The electromagnetic valve of 1 system with absorbent carbon

Removal

PERFORMANCE ORDER
1. Separate the shtekerny socket of the oxygen sensor. The Shtekerny socket is strengthened at a forward wall of a cabin. the 6-cylinder engine has 2 oxygen sensors. Respectively there are 4 shtekerny sockets: 2 for heating of sensors and 2 for signals. Sockets for heating of oxygen sensors black also are located by Shtekernye at the left and on the right at the shtekerny panel of a forward wall. Shtekernye sockets for signals of sensors are slightly below the shtekerny panel, near black shtekerny sockets.
2. All pulling together collars dismiss, thus mark the provision of collars by a felt-tip pen.
3. Turn out the oxygen sensor from a branch pipe of the fulfilled gases.

Installation

PERFORMANCE ORDER
1. A carving of the oxygen sensor grease with assembly G5 paste.
Prevention

Cмазка should not reach sides on the case of the oxygen sensor.


2. Insert the oxygen sensor and tighten the moment of 50 Nanometers.
3. Connect shtekerny sockets of chains of heating and a signal.
4. Electric wires fix coupling collars. Pay attention to that coupling collars were established on the same place where they were before removal. It is necessary to avoid a contact of wires with final system.