Audi 100/A6

1990-1997 of release

Repair and car operation



Audi 100/A6
+ 1. Maintenance instruction
+ 2. Maintenance
+ 3. Engines
+ 3.2. Diesel engines
+ 3.3. Removal and partition of engines
+ 4. Cooling system
+ 5. Heating and ventilation
+ 6. Fuel system
+ 7. Exhaust system
+ 8. Systems of start, ignition
+ 9. Transmission
+ 10. Brake system
- 11. Suspension brackets, steering
   11.2. Technical characteristics
   11.3. General description of adjustment of wheels
   + 11.4. Forward suspension bracket
   - 11.5. Back suspension bracket
      11.5.2. Bearings of a nave of a back wheel
      11.5.3. Pin of a back wheel
      11.5.4. Rack of a back suspension bracket
      11.5.5. Cross-section draft of a back suspension bracket
      11.5.6. Stabilizer of cross-section stability of a back suspension bracket
      11.5.7. Cross-piece of a back suspension bracket
      11.5.8. System of adjustment of height of a back suspension bracket
      11.5.9. Elements of system of adjustment of height of a back suspension bracket
   + 11.6. Steering
   + 11.7. Semi-axes
   11.8. Easily and easy
   11.9. Maintenance of system of a steering
   11.10. Diagnostics of malfunctions of system of a steering
+ 12. Body
+ 13. Electric equipment
+ 14. Good advice


ff85f19c

11.5.9. Elements of system of adjustment of height of a back suspension bracket

GENERAL INFORMATION

HYDRAULIC PUMP

Look subsection 11.6.7.

ADJUSTING VALVE

Removal
PERFORMANCE ORDER
1. Put on a tube piece the pumping valve (it is specified by an arrow) and let out pressure from system, having opened the pumping valve on the left accumulator.
2. Disconnect draft from the valve lever.
3. Turn off nuts of connections and disconnect hydraulic tubes from the valve.
4. Turn off fixing bolts and remove the valve.

Installation

Installation is carried out upside-down removals.

Adjustment

PERFORMANCE ORDER
1. Establish wooden blocks in height of 342 mm under the bottom of the car and load a car luggage carrier so that the bottom of the car concerned blocks.
2. Weaken a nut of fastening of connecting draft of the valve to a back axis. Combine an opening in the valve lever with an opening in the case of the valve and block the lever in this situation, having inserted into openings a drill or a bolt.
3. Tighten a fixing nut of connecting draft till the demanded moment of an inhaling.

ACCUMULATOR

Removal

PERFORMANCE ORDER
1. Let out pressure from adjustment system.
2. Turn off nuts of connections and disconnect hydraulic tubes.
3. Turn off fixing bolts and remove the accumulator.

Installation

Installation is carried out upside-down removals.

SUSPENSION BRACKET RACKS

Look subsection 11.5.4.